This approach also minimizes sample turbidity, which can create bias and "false positives." Earlier to the release of the EPA's Low Flow Sampling Procedures, groundwater sampling was primarily done using a volume average method that used bailers or pumps to swiftly and efficiently extract significant quantities of water from the good casing.
The sampling procedure begins with a purge of stagnant water in the well, followed by the collection of samples. The turbidity and other properties of the stagnant water are measured as it is pulled up. The monitoring data informs the environmental technician when the water has transitioned from stagnant well water to water drawn from a nearby aquifer. This is a prompt to start collecting groundwater samples.
Necessary Equipment for Low Flow Sampling
Your low flow sampling project will include purging the water underground at a constant rate, regardless of what you're measuring or testing. This is done to guarantee that the purging method causes the least amount of disruption to the site, as speeding up the process could affect sample results.
You'll need a low flow sampling pump to filter the water. Because there are so many different types of pumps on the market, you must choose the one that best suits your needs.
You must go with a trusted brand like ERE inc.(Environmental Remediation Equipment Inc.) that offers a groundwater sampling pump, well water sampler, high and standard performance proactive pumps, and other water sampling equipment for quality water sampling.
The cost of various pumps will almost certainly be a factor, so make sure to look into all of your possibilities before deciding on a low flow sampling pump.
Purged water won't help you much unless you have the tools to do the tests you need on the samples, which is why a water quality monitoring device is so crucial.
For effective low flow sampling, careful monitoring of the water being purged and collected is required. You'll need a water level monitoring instrument to help you figure out how much water is underground and how much is being drawn down.
A Heron and Solinst water level meter is the most user-friendly of these units. They may be used to rapidly and easily measure water levels, and they come in two modes: static (for measuring water depth) and drawdown (for low flow sampling).
Tubing for low-flow sampling comes in a variety of materials, each with its own set of benefits and drawbacks. Polyethene tubing is popular because of its strength and durability, while Teflon tubing is popular because it is resistant to a wide range of solvents and acids.
Important Factors to Consider for Low Flow Sampling
Low-flow sampling isn't an easy procedure. There is a risk of improper groundwater samples, damage to the test site, and, in some situations, a risk to the personnel working on the site themselves if proper care and caution are not followed.
There are several crucial elements to consider to minimize these risks and guarantee that your low-flow sampling process runs smoothly throughout.
There's a chance that the groundwater you're monitoring includes trace pollutants while you're doing low-flow sampling. Regardless of whether there is one or not, it is recommended that each time a different place is sampled, a clean pair of non-powdered disposable gloves be worn.
When working with samples suspected of harboring high levels of pollutants, it's critical to keep them distinct from samples with low levels or no evidence of contaminants.
It's also critical to have a firm grasp of what you're testing for. When testing for volatile organic compounds (VOCs), for example, if adequate pumping protocols are not followed, the VOCs may be lost throughout the collecting process. To reduce the risk of loss, it's best to avoid using vacuum pumps and avoid tampering with the tubing, which could cause a pressure shift.
Finally, when working with your obtained samples, keep a few general handling and preservation suggestions in mind.